DTC No. P1B00-55 Main CPU is not done config
MONITOR EXECUTION
Continuous
MONITOR EXECUTION CONDITIONS (Other monitor and Sensor)
Other Monitor (There is no temporary DTC set in memory for the item monitored below)
Not applicable
Sensor (The sensor below is determined to be normal)
Not applicable
DTC SET CONDITIONS
Logic Flow Chart
Check Condition
Battery management unit (BMU) wake-up: ON
Judgment Criterion
The configuration data status is in the not programmed condition.
OBD-II DRIVE CYCLE PATTERN
Refer to OBD-II Drive Cycle
OBD-II DRIVE CYCLE
.
TROUBLESHOOTING HINTS
The vehicle specification writing for BMU is not performed.
DIAGNOSIS
Required Special Tools:
MB992744: Vehicle communication interface-Lite (V.C.I.-Lite)
MB992745: V.C.I.-Lite main harness A
MB992747: V.C.I.-Lite USB cable short
MB992748: V.C.I.-Lite USB cable long
1.
BMU vehicle specification writing
(1)
Perform the vehicle specification writing for BMU (Refer to
VEHICLE SPECIFICATION WRITING
).
(2)
Erase the DTC set in the BMU2.
(3)
Erase the DTC set in the BMU.
(4)
2.
Test the OBD-II drive cycle.
(1)
Carry out a test drive with the drive cycle pattern. Refer to OBD-II Drive Cycle
OBD-II DRIVE CYCLE
.
(2)
Check the DTC.
Is the DTC set?
Retry the troubleshooting.