10 | Water pump actuate(EV) | - IGCT control power supply voltage: 8 V to 16 V
- Power supply mode of the electric motor switch: ON
- Vehicle speed: 0 km/h (0 mph)
- The DTCs related to electric water pump are not set as current trouble.
- The EV coolant level is between the MAX and MIN mark of the condenser tank and air bleeding is already performed by the special function item No. 10 "EV Coolant refilling control" (Refer to SPECIAL FUNCTION).
| Select ON to actuate the electric water pump. | ON/OFF |
20 | Water pump power supply relay | - IGCT control power supply voltage: 8 V to 16 V
- Power supply mode of the electric motor switch: ON
- Vehicle speed: 0 km/h (0 mph)
| Select ON to actuate the water/oil pump relay. | ON/OFF |
40 | Control signal for Shift Position Lamp P | - IGCT control power supply voltage: 8 V to 16 V
- Power supply mode of the electric motor switch: ON
- READY indicator: OFF
- Vehicle speed: 0 km/h (0 mph)
| Select ON to illuminate the selector position lamp (P). | ON/OFF |
50 | Control signal for Shift Position Lamp R | - IGCT control power supply voltage: 8 V to 16 V
- Power supply mode of the electric motor switch: ON
- READY indicator: OFF
- Vehicle speed: 0 km/h (0 mph)
| Select ON to illuminate the selector position lamp (R). | ON/OFF |
60 | Control signal for Shift Position Lamp N | - IGCT control power supply voltage: 8 V to 16 V
- Power supply mode of the electric motor switch: ON
- READY indicator: OFF
- Vehicle speed: 0 km/h (0 mph)
| Select ON to illuminate the selector position lamp (N). | ON/OFF |
70 | Control signal for Shift Position Lamp D | - IGCT control power supply voltage: 8 V to 16 V
- Power supply mode of the electric motor switch: ON
- READY indicator: OFF
- Vehicle speed: 0 km/h (0 mph)
| Select ON to illuminate the selector position lamp (D). | ON/OFF |
80 | Control signal for Shift Position Lamp B | - IGCT control power supply voltage: 8 V to 16 V
- Power supply mode of the electric motor switch: ON
- READY indicator: OFF
- Vehicle speed: 0 km/h (0 mph)
| Select ON to illuminate the selector position lamp (B). | ON/OFF |
120 | Red LED light | - IGCT control power supply voltage: 8 V to 16 V
- Power supply mode of the electric motor switch: ON
- Vehicle speed: 0 km/h (0 mph)
| Select ON to illuminate the red LED of the EV charger light (charging indicator). | ON/OFF |
130 | Green LED light | - IGCT control power supply voltage: 8 V to 16 V
- Power supply mode of the electric motor switch: ON
- Vehicle speed: 0 km/h (0 mph)
| Select ON to illuminate the green LED of the EV charger light (charging indicator). | ON/OFF |
140 | Blue LED light | - IGCT control power supply voltage: 8 V to 16 V
- Power supply mode of the electric motor switch: ON
- Vehicle speed: 0 km/h (0 mph)
| Select ON to illuminate the blue LED of the EV charger light (charging indicator). | ON/OFF |
150 | On vehicle inverter flag | - IGCT control power supply voltage: 10 V to 16 V
- READY indicator: ON
- AC main switch: ON
| Select ON to actuate the AC inverter. | ON/OFF |
180 | V2H connector power supply relay control | - IGCT control power supply voltage: 8 V to 16 V
- Power supply mode of the electric motor switch: ON
- Vehicle speed: 0 km/h (0 mph)
| Select ON to actuate the V2H relay. | ON/OFF |
190 | DCDC Voltage request | - IGCT control power supply voltage: 9 V to 16 V
- READY indicator: ON
- Other electric equipment should not be used.
| The DC-DC converter is actuated according to the set voltage (V). | 13 to 15.5 V |
220 | Radiator fan control | - Power supply mode of the electric motor switch: ON
| Select the percentage of the fan speed and activate the radiator fan (RH) or radiator fan (LH) by the selected speed. | 0%/15%/30%/45%/60%/75%/90% |