DTC P060B-00: A/D converter malfunction
 
 
 
 
TECHNICAL DESCRIPTION
Monitors whether input voltage from the mass airflow sensor is normally converted into a digital signal in the ECM.
 
 
MONITOR EXECUTION
Continuous.
 
 
MONITOR EXECUTION CONDITIONS (Other monitor and Sensor)
Other Monitor (There is no temporary DTC set in memory for the item monitored below)
  • Not applicable
Sensor (The sensor below is determined to be normal)
  • Not applicable
 
 
DTC SET CONDITIONS
Check Condition
  • Power supply mode of electric motor switch is ON.
Judgment Criterion
  • When the input voltage from the mass airflow sensor is periodically 0 volt for 0.45 second, the digital value of the input voltage indicates 0.2 volt or more.
 
 
FAIL-SAFE AND BACKUP FUNCTION
Throttle opening degree position is in default position.
 
 
OBD-II DRIVE CYCLE PATTERN
None.
 
 
TROUBLESHOOTING HINTS (The most likely causes for this code to be set are:)
ECM failed.
 
 
DIAGNOSIS
Required Special Tools:
  • MB992744: Vehicle communication interface-Lite (V.C.I.-Lite)
  • MB992745: V.C.I.-Lite main harness A
  • MB992747: V.C.I.-Lite USB cable short
  • MB992748: V.C.I.-Lite USB cable long
1.STEP 1. Using scan tool (M.U.T.-III SE), DTC recheck after erasing DTC.
After erasing the DTC, check again to see if the DTC is set again.
(1) Use scan tool (M.U.T.-III SE) to erase the DTC.
(2) Turn OFF the power supply mode of the electric motor switch.
(3) Turn ON the power supply mode of the electric motor switch.
(4) Use scan tool (M.U.T.-III SE) to recheck the DTC.
Q: Is DTC P060B-00 set?
Intermittent malfunction (Refer to GENERAL INFORMATION, General Information – How to Use Troubleshooting/Inspection Service Points – How to Cope with Intermittent Malfunctions HOW TO COPE WITH INTERMITTENT MALFUNCTIONS).