LINEAR A/F SENSOR CHECK
1.
Disconnect the linear A/F sensor connector.
2.
Measure the resistance between terminal No. 3 and No. 4 of the linear A/F sensor connector.
Standard value: 2.7 – 4.6 Ω [at 23°C (73°F)]
3.
If the resistance deviates from the standard value, replace the linear A/F sensor (Refer to Engine, Motor and Emission Control