[Previous][Next]
Diagnosis Procedure
1.CHECK LVDS CABLE 1
  1. Turn ignition switch OFF.
  2. Check the connection status of the LVDS cable connector. (multi-around monitor control unit side, wire to wire, and front camera side)
Is inspection result normal?
.
Connect the LVDS cable connector correctly.
 
2.CHECK LVDS CABLE 2
  1. Turn ignition switch OFF.
  2. Disconnect multi-around monitor control unit connector and front camera connector.
  3. Check continuity between multi-around monitor control unit harness connector and front camera harness connector.
    Multi-around monitor control unitFront cameraContinuity
    ConnectorTerminalsConnectorTerminals
    B8139B841Existed
    402
  4. Check continuity between multi-around monitor control unit harness connector and ground.
    Multi-around monitor control unitGroundContinuity
    ConnectorTerminal
    B8139Not existed
Is inspection result normal?
Replace front camera. Refer to Removal and Installation.
Replace LVDS cable.