Diagnosis Procedure
1.
CHECK LVDS CABLE 1
Turn ignition switch OFF.
Check the connection status of the LVDS cable connector. (multi-around monitor control unit side, wire to wire, and front camera side)
Is inspection result normal?
.
Connect the LVDS cable connector correctly.
2.
CHECK LVDS CABLE 2
Turn ignition switch OFF.
Disconnect multi-around monitor control unit connector and front camera connector.
Check continuity between multi-around monitor control unit harness connector and front camera harness connector.
Multi-around monitor control unit
Front camera
Continuity
Connector
Terminals
Connector
Terminals
B81
39
B84
1
Existed
40
2
Check continuity between multi-around monitor control unit harness connector and ground.
Multi-around monitor control unit
Ground
Continuity
Connector
Terminal
B81
39
Not existed
Is inspection result normal?
Replace front camera. Refer to
Removal and Installation
.
Replace LVDS cable.