Diagnosis Procedure
1.
CHECK FUSE AND FUSIBLE LINK
Ignition switch OFF.
Check that the following IPDM E/R fuse and fusible link is not blown (open).
Signal name
Fuse and Fusible link No.
Battery power supply
B (140A)
X (30A)
Is the fuse and fusible link blown (open)?
Replace the blown (open) fuse or fusible link after repairing the affected circuit if a fuse or fusible link is blown (open).
.
2.
CHECK BATTERY POWER SUPPLY VOLTAGE
Disconnect IPDM E/R connector.
Check voltage between IPDM E/R harness connector and ground.
+
-
Voltage
IPDM E/R
Connector
Terminal
F41
81
Ground
6 – 16 V
Is the inspection result normal?
Replace IPDM E/R. Refer to
Removal and Installation
.
Repair the battery power supply circuit.