[Previous][Next]
Diagnosis Procedure
1.CHECK Power liftgate SERIAL COMMUNICATION SIGNAL
  1. Ignition switch ON.
  2. Check signal between BCM harness connector and ground using oscilloscope.
    (+)(–)Signal
    (Reference value)
    BCM
    ConnectorTerminal
    B2683Ground
Is the inspection result normal?
INSPECTION END
.
 
2.CHECK Power liftgate SERIAL COMMUNICATION CIRCUIT
  1. Ignition switch OFF.
  2. Disconnect hands free sensor control unit connector and BCM connector.
  3. Check continuity between hands free sensor control unit harness connector and BCM harness connector.
    Hands free sensor control unitBCMContinuity
    ConnectorTerminal ConnectorTerminal
    B4521B2683Existed
  4. Check continuity between hands free sensor control unit harness connector and ground.
    Hands free sensor control unitContinuity
    ConnectorTerminal
    B4521GroundNot existed
Is the inspection result normal?
Replace BCM. Refer to Removal and Installation.
Repair or replace harness.