1.CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR CONNECTOR FOR WATER
2.CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR POWER SUPPLY
3.CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR POWER SUPPLY CIRCUIT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between EVAP control system pressure sensor harness connector and ECM harness connector.
+ | − | Continuity |
EVAP control system pressure sensor | ECM |
Connector | Terminal | Connector | Terminal |
C51 | 3 | E16 | 133 | Existed |
- Also check harness for short to ground and to power.
Is the inspection result normal?
Perform the trouble diagnosis for power supply circuit. Repair or replace error-detected parts
4.CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR GROUND CIRCUIT
5.CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR SIGNAL CIRCUIT
- Check the continuity between EVAP control system pressure sensor harness connector and ECM harness connector.
+ | − | Continuity |
EVAP control system pressure sensor | ECM |
Connector | Terminal | Connector | Terminal |
C51 | 2 | E16 | 129 | Existed |
- Also check harness for short to ground and to power.
Is the inspection result normal?
Repair or replace error-detected parts.