| Terminals | Continuity | |||
| Combination meter | Illumination control switch | |||
| Connector | Terminal | Connector | Terminal | |
| M77 | 25 | M3 | 6 | Existed |
| 31 | 7 | |||
| 32 | 4 | |||
| Combination meter | Ground | Continuity | |
| Connector | Terminal | ||
| M77 | 25 | Not existed | |
| 31 | |||
| 32 | |||
Repair harness or connector.
.
Replace combination meter. Refer to Removal and Installation
.
Replace illumination control switch. Refer to Removal and InstallationRemoval and Installation
.