| Signal name | Fuse and Fusible link No. |
| Battery power supply | B (140A) |
| X (30A) |
Replace the blown (open) fuse or fusible link after repairing the affected circuit if a fuse or fusible link is blown (open).| + | - | Voltage | |
| IPDM E/R | |||
| Connector | Terminal | ||
| F41 | 81 | Ground | 6 – 16 V |
Replace IPDM E/R. Refer to Removal and Installation
.
Repair the battery power supply circuit.