Work Procedure
caution
Always use M.U.T.-III SE for the side G sensor calibration. (It cannot be adjusted other than with M.U.T.-III SE.)
1.
CHECK THE VEHICLE STATUS
Steer the steering wheel to the straight-ahead position. Stop the vehicle on level surface.
Stop the engine.
Ignition switch OFF (Auto ACC function OFF).
Is the vehicle stopped in the straight-ahead position on level surface?
.
Steer the steering wheel to the straight-ahead position. Stop the vehicle on level surface.
2.
PERFORM SIDE G SENSOR CALIBRATION
caution
Never allow passenger or load on the vehicle.
Never apply vibration to the vehicle body when opening or closing door during calibration.
With M.U.T.-III SE
Ignition switch ON.
caution
Never start engine.
Select “ABS”, “Sensor calibration(in "Special function")” and “SIDE G SENSOR CALIBRATION” in this order.
Select “OK”.
After "Completed" is displayed, wait bout 10 seconds and press "OK".
Ignition switch OFF (Auto ACC function OFF) and then it ON again.
caution
Be sure to perform the operation above.
:
.
3.
CHECK DATA MONITOR
With M.U.T.-III SE
Drive the vehicle. Steer the steering wheel to the straight-ahead position. Stop the vehicle on level surface.
Select “ABS”, “Data List”, and “Side G sensor” in this order. Check that the signal is within the specified value. Refer to
Reference Value
.
Is the inspection result normal?
.
.
4.
ERASE SELF-DIAGNOSIS MEMORY
With M.U.T.-III SE
Erase self-diagnosis result of all systems.
Are the memories erased?
INSPECTION END
Check the items indicated by the self-diagnosis.