Work Procedure
 
 
cautionAlways use M.U.T.-III SE for the decel G sensor calibration. (It cannot be adjusted other than with M.U.T.-III SE.)
1.CHECK THE VEHICLE STATUS
  1. Steer the steering wheel to the straight-ahead position. Stop the vehicle on level surface.
  2. Stop the engine.
  3. Ignition switch OFF (Auto ACC function OFF).
Is the vehicle stopped in the straight-ahead position on level surface?
.
Steer the steering wheel to the straight-ahead position. Stop the vehicle on level surface.
 
2.PERFORM DECEL G SENSOR CALIBRATION
caution
  • Never allow passenger or load on the vehicle.
  • Never apply vibration to the vehicle body when opening or closing door during calibration.
With M.U.T.-III SE
  1. Ignition switch ON.
    cautionNever start engine.
  2. Select “ABS”, “Sensor calibration(in "Special function")” and “DECEL G SENSOR CALIBRATION” in this order.
  3. Select “OK”.
  4. After "Completed" is displayed, wait bout 10 seconds and press "OK".
  5. Ignition switch OFF (Auto ACC function OFF) and then it ON again.
    cautionBe sure to perform the operation above.
: .
 
3.CHECK DATA MONITOR
With M.U.T.-III SE
  1. Drive the vehicle. Steer the steering wheel to the straight-ahead position. Stop the vehicle on level surface.
  2. Select “ABS”, "Data List", and “Decel G sensor” in this order. Check that the signal is within the specified value. Refer to Reference Value.
Is the inspection result normal?
.
.
 
4.ERASE SELF-DIAGNOSIS MEMORY
With M.U.T.-III SE
Erase self-diagnosis result of “ABS”.
Are the memories erased?
End of work.
Check the items indicated by the self-diagnosis.