2.CHECK FUEL RAIL PRESSURE (FRP) SENSOR POWER SUPPLY-1
3.CHECK FRP SENSOR POWER SUPPLY-2
Check the voltage between FRP sensor harness connector and the ground.| + | − | Voltage (Approx.) |
| FRP sensor |
| Connector | Terminal |
| F79 | 3 | Ground | 5 V |
Is inspection result normal?
4.CHECK FRP SENSOR POWER SUPPLY CIRCUIT FOR OPEN AND SHORT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between FRP sensor harness connector and ECM harness connector.
| FRP sensor | ECM | Continuity |
| Connector | Terminal | Connector | Terminal |
| F79 | 3 | F51 | 61 | Existed |
- Also check harness for short to power.
Is inspection result normal?
Perform trouble diagnosis for power supply circuit.
Repair or replace error-detected parts.
5.CHECK FRP SENSOR GROUND CIRCUIT FOR OPEN AND SHORT
6.CHECK ECM GROUND CIRCUIT FOR OPEN AND SHORT
- Check the continuity between ECM harness connector and ground.
| ECM | Ground | Continuity |
| Connector | Terminal |
| F91 | 4 | Ground | Existed |
| E16 | 156 |
| 157 |
| 160 |
- Also check harness for short to power.
Is the inspection result normal?
INSPECTION END
Repair or replace error-detected parts.
7.CHECK FRP SENSOR SIGNAL CIRCUIT FOR OPEN AND SHORT