[Previous][Next]
CHARGING
Use the refrigerant recovery station to charge the refrigerant.
 
 
METHOD BY USING REFRIGERANT RECOVERY AND RECYCLING UNIT
Using the refrigerant recovery and recycling unit, refill the refrigerant.
noteRefer to the Refrigerant Recovery and Recycling Unit's Instruction Manual for operation of the unit.
 
 
 
DISCHARGING SYSTEM
Use the refrigerant recovery unit to discharge refrigerant gas from the system.
noteRefer to the Refrigerant Recovery and Recycling Unit's Instruction Manual for operation of the unit.
 
 
 
REFILLING OF OIL IN THE A/C SYSTEM
Too little oil will provide inadequate compressor lubrication and cause a compressor failure. Too much oil will increase discharge air temperature.
When a compressor is installed at the factory, it contains 70 cm3 (2.4 fl.oz) of refrigerant oil. While the A/C system is in operation, the oil is carried through the entire system by the refrigerant. Some of this oil will be trapped and retained in various parts of the system.
When the following system components are changed, it is necessary to add oil to the system to replace the oil being removed with the component.
Compressor oil: PAG 46A
Quantity:
  • Evaporator: 25 cm3 (0.8 fl.oz)
  • Condenser: 15 cm3 (0.5 fl.oz)
  • Suction hose: 10 cm3 (0.3 fl.oz)