DIAGNOSTIC ITEM 26: Diagnose when the scan tool cannot receive the data sent by combination meter.
 
 
cautionWhen servicing a CAN bus line, ground yourself by touching a metal object such as an unpainted water pipe. If you fail to do so, a component connected to the CAN bus line may be damaged.
 
 
 
 
FUNCTION
If the scan tool MB991958 cannot communicate with the combination meter, this diagnosis result will be set.
 
 
TROUBLE JUDGMENT CONDITIONS
If a communication flag is not set for the combination meter, the ETACS-ECU determines that there is a failure.
 
 
TROUBLESHOOTING HINTS
  • Malfunction of the connector [joint connector (CAN1) or combination meter connector improperly connected]
  • Malfunction of the wiring harness [open circuit between the combination meter connector and the joint connector (CAN1), power supply circuit to the combination meter]
  • Malfunction of the combination meter
 
 
DIAGNOSIS
Required Special Tools:
  • MB991223: Harness Set
  • MB992006: Extra Fine Probe
STEP 1. Check joint connector (CAN1) C-05 and combination meter connector C-203 for loose, corroded or damaged terminals, or terminals pushed back in the connector.
cautionThe strand end of the twisted wire should be within 10 cm (4 inches) from the connector. For details refer to .
Are joint connector (CAN1) C-05 and combination meter connector C-203 in good condition?
Go to Step 2.
Repair the damaged parts.
 
STEP 2. Check the wiring harness between joint connector (CAN1) C-05 and combination meter connector C-203 for open circuit.
cautionStrictly observe the specified wiring harness repair procedure. For details refer to .
(1) Disconnect joint connector (CAN1) C-05 and combination meter connector C-203, and check the wiring harness.
(2) Check the wiring harness between joint connector (CAN1) C-05 (terminal No.7) and combination meter connector C-203 (terminal No.14)
OK: Continuity exists (2 ohms or less)
(3) Check the wiring harness between joint connector (CAN1) C-05 (terminal No.18) and combination meter connector C-203 (terminal No.15)
OK: Continuity exists (2 ohms or less)
Is the wiring harness between joint connector (CAN1) C-05 and combination meter connector C-203 in good condition?
Check the power supply circuit of the combination meter. Refer to GROUP 54A, Combination Meter - Diagnosis .
Repair the wiring harness between joint connector (CAN1) C-05 and combination meter connector C-203.