1. Remove the hazard indicator assembly.
2. Connect the battery (+) terminal with the hazard indicator assembly connector terminal No. 13. Then, check if the theft-alarm indicator is illuminated when the battery (-) terminal and the center panel unit connector terminal No. 12 are connected.
3. If the theft-alarm indicator is illuminated, it is judged good.
note | Make sure that the polarity is correct. |