[Previous][Next]
DTC B1200: Malfunction of odometer
 
 
 
 
TROUBLE JUDGEMENT
If the odometer information, which is stored in the combination meter, is abnormal when the ignition switch at the ON position and the system voltage is 10 -16 volts (data from ETACS-ECU), DTC B1200 is stored.
 
 
TROUBLESHOOTING HINTS
The combination meter may be defective.
 
 
DIAGNOSIS
STEP 1. Using scan tool MB991958, read the combination meter diagnostic trouble code.
Check if DTC is set to the combination meter.
(1)
cautionTo prevent damage to scan tool MB991958, always turn the ignition switch to the "LOCK" (OFF) position before connecting or disconnecting scan tool MB991958.
Connect scan tool MB991958. Refer to "How to connect the Scan Tool (M.U.T.-III) ."
(2) Turn the ignition switch to the "ON" position.
(3) Erase the DTC.
(4) Turn the ignition switch from "LOCK" (OFF) position to "ON" position.
(5) Check if diagnostic trouble code is set.
Is the DTC set?
Replace the combination meter, and then go to Step 2.
The trouble can be an intermittent malfunction (Refer to GROUP 00, How to Cope with Intermittent Malfunction ).
 
STEP 2. Recheck for diagnostic trouble code.
Check if DTC is set to the combination meter.
(1) Erase the DTC.
(2) Turn the ignition switch from "LOCK" (OFF) position to "ON" position.
(3) Check if diagnostic trouble code is set.
Is the DTC set?
Go to Step 1.
The procedure is complete.