CLOCK SPRING
If any malfunction is found in the following inspections, replace the clock spring with a new one.
1. Check the connectors and protective tubes for damage and the terminal for deformation.
2. Check the case for damage.
3. Check that the continuity exists between the following connector terminals.- C-312 connector terminal 1 and C-304 connector terminal 1
- C-312 connector terminal 2 and C-304 connector terminal 2
- C-312 connector terminal 3 and C-304 connector terminal 3
- C-312 connector terminal 5 and C-304 connector terminal 5
- C-312 connector terminal 6 and C-304 connector terminal 6
- C-312 connector terminal 7 and C-304 connector terminal 7
4. As shown in the Figure, connect the circuit tester to special tool extra fine probe (MB992006) and check to see that there is a charge between the terminals.