INSPECTION
LIFTGATE LOCK RELEASE HANDLE (LIFTGATE OPEN SWITCH) CHECK
<VEHICLES WITHOUT KOS>
Switch position
Terminal number
Normal value
Push (open)
1 - 2
Continuity exists (2 Ω or less)
Release
1 - 2
No continuity
<VEHICLES WITH KOS>
Switch position
Terminal number
Normal value
Push (open)
1 - 2
Continuity exists (2 Ω or less)
Release
1 - 2
No continuity
LIFTGATE LOCK RELEASE HANDLE (LIFTGATE LOCK SWITCH) CHECK <VEHICLES WITH KOS>
Switch position
Terminal number
Normal value
Push (lock)
2 - 3
Continuity exists (2 Ω or less)
Release
2 - 3
No continuity
LIFTGATE LOCK ACTUATOR CHECK
Lever position
Battery connection
Lever operation
At the "SET" position
Connect terminal 2 to negative battery terminal.
Connect terminal 1 to positive battery terminal.
Lever moves from "SET" to "OPEN" position.
LIFTGATE LATCH SWITCH CHECK
Claw position
Terminal number
Normal value
Unlatch (ON)/ Half-latch (ON)
1 - Ground
Continuity exists (2 Ω or less)
Full-latch (OFF)
1 - Ground
No continuity