INSPECTION
FCM AND ULTRASONIC MISACCELERATION MITIGATION SYSTEM ON/OFF SWITCH CHECK
Switch resistance check
Switch position
Terminal number
Specified condition
OFF
7 - 10
No continuity
ON
Continuity exists (2 Ω or less)
Illumination check
Auxiliary battery voltage
Terminal number
Normal condition
At no energization
8 (+) - 9 (-)
Not illuminated
With current supply
Illuminated