[Previous][Next]
BRAKE FLUID PRESSURE SENSOR CALIBRATION
caution
  • Prior to calibration, check that no brake fluid pressure sensor-related diagnostic trouble codes are set.
  • After the following procedure is complete, carry out calibration to let the ASC-ECU learn the neutral position of the brake fluid pressure sensor.
    • During diagnosis according to diagnostic trouble code No. C123A
    • ASC-ECU replacement
  • During the calibration, the brake pedal should be released (the stoplight switch should be off).
1. Park the vehicle on a level surface.
2.
cautionBefore connecting or disconnecting scan tool, always turn the ignition switch to the LOCK (OFF) position.
Before setting scan tool (M.U.T.-III), turn the ignition key to the LOCK (OFF) position.
3. Turn the ignition switch to the ON position.
4. Select "ABS/ASC/ASTC/WSS."
5. Select "Special function."
6. Select "Sensor calibration."
7. Select "Master cylinder pressure sensor calibration."
8. Before removing scan tool (M.U.T.-III) from the vehicle, turn the ignition key to the LOCK (OFF) position.