STEERING WHEEL SENSOR CALIBRATION
cautionAfter the next operation has been completed, carry out the following two operations:
  • Alignment adjustment <Front>
  • Steering wheel sensor (column switch assembly) replacement, removal, installation
  • ASC-ECU replacement
  1. Update the neutral position stored in the steering wheel sensor.
  2. Reset the calibrated value of the steering angle stored in ASC-ECU.
  • Before performing the calibration, check if the steering wheel sensor-related diagnostic trouble code is set in ASC-ECU.
  • When the diagnostic trouble code other than C121A is set, carry out inspection according to each troubleshooting procedure.
1. Place the vehicle on a level surface with its road wheels in the straight ahead position.
2.
cautionBefore connecting or disconnecting scan tool, always turn the ignition switch to the LOCK (OFF) position.
Before setting scan tool (M.U.T.-III), turn the ignition key to the LOCK (OFF) position.
3. Turn the ignition switch to the ON position.
4. Select "Steering Angle Sensor."
5. Select "Special function."
6. Select "SAS Calibration."
7. Select "SAS Calibration."
8. Select "Special function" under "Steering angle sensor".
note
  • If the steering angle sensor neutral point has been learned, the display will show "If SAS needs re-calibration, execute SAS calibration after executing SAS Initialization". If yes, press "OK" button.
  • At this time, if the steering angle sensor neutral point has been learned, the display will show "Do you want to start? Note This operation will dear DTCs". Then, press "OK" button.
9. The display should show "SAS Calibration: Do you want to start?". Then press the OK button.
notePlease execute after making a tire and a steering wheel straight.
10. The display should show "Completed." Press "OK" button.
11. Turn the ignition switch to "LOCK" (OFF) position.
12. Turn the ignition switch to the ON position.
13. Select "ABS/ASC/ASTC/WSS."
14. Select "Special function."
15. Select "Sensor calibration."
16. Select "Steering angle sensor calibration."
17. The screen displays "SAS calibration: The selected command will be executed. Are you sure? Caution: Confirm the execution conditions." Then press "OK" button.
18. "Executed: The command was executed." will be shown. Then press "OK" button.
19. Select "Diagnostic trouble code" under "ABS/ASC/ASTC/WSS". If the diagnostic trouble code "C2205 SAS internal failure (past trouble)" is set, clear it.
20. Learning neutral point complete
21. Before removing scan tool (M.U.T.-III) from the vehicle, turn the ignition key to the "LOCK" (OFF) position.