[Previous][Next]
DTC P2765: Malfunction of Turbine Speed Sensor
 
 
 
 
DIAGNOSTIC FUNCTION
The TCM determines whether the system is defective by monitoring the turbine speed sensor.
 
 
DESCRIPTIONS OF MONITOR METHODS
  • The turbine speed remains at 150 r/min or less for five seconds when two seconds or more have elapsed after the selector lever position is changed, the selector lever is not at P or N range, the engine speed is 250 r/min or more, and the primary pulley speed is 500 r/min or more.
  • 0.5 seconds after the turbine speed has dropped abruptly from 1,000 r/min or more to 150 r/min or less
  • Turbine speed is found abnormal by comparing the engine speed and the primary pulley speed.
 
 
MONITOR EXECUTION
  • Transmission range: D
  • Engine speed: 450 r/min or more
  • Voltage of battery: 10 volts or more.
 
 
MONITOR EXECUTION CONDITIONS (OTHER MONITOR AND SENSOR)
Other Monitor (There is no temporary DTC stored in memory for the item monitored below)
  • P0715: Malfunction of primary pulley speed sensor
  • P0720: Malfunction of secondary pulley speed sensor
  • P2720, P2721: Malfunction of select pressure solenoid valve
  • P2763, P2764: Malfunction of lock-up solenoid valve
Sensor (The sensor below is determined to be normal)
  • Primary pulley speed sensor
  • Secondary pulley speed sensor
 
 
LOGIC FLOW CHARTS (Monitor Sequence-Input Rationality-Low (Open/Low revolution))
 
 
LOGIC FLOW CHARTS (Monitor Sequence-Input Open Circuit)
 
 
LOGIC FLOW CHARTS (Monitor Sequence-Input Other Rationality)
 
 
DTC SET CONDITIONS
Check Conditions <Input Rationality-Low (Open/Low revolution)>
  • Voltage of battery: 10 volts or more.
  • Transmission range switch position: D or R.
  • Engine speed: 450 r/min or more.
  • Primary pulley speed: 500 r/min or more.
Check Conditions <Input Open Circuit>
  • Voltage of battery: 10 volts or more.
  • Turbine speed at 10 millisecond before: 1,000 r/min or more.
Check Conditions <Input Other Rationality>
  • Voltage of battery: 10 volts or more.
  • Transmission range switch position: D.
  • Engine speed: 450 r/min or more.
  • Primary pulley speed: 300 r/min or more.
  • Secondary pulley speed: 300 r/min or more.
  • Turbine speed: 300 r/min or more.
  • Engine speed - Primary pulley speed: 1,000 r/min or less.
  • Torque converter clutch status: Engaged.
Judgment Criteria <Input Rationality-Low (Open/Low revolution)>
  • Turbine speed [Primary pulley speed: 500 r/min or more]: Less than 150 r/min. (5 seconds)
Judgment Criteria <Input Open Circuit>
  • Turbine speed [Turbine speed at 10 millisecond before: 1,000 r/min or more]: 150 r/min or less. (0.5 second)
Judgment Criteria <Input Other Rationality>
  • Turbine speed - Engine speed: More than 1,000 r/min. (5 seconds)
  • Turbine speed - Primary pulley speed: More than 1,000 r/min. (5 seconds)
 
 
OBD-II DRIVE CYCLE PATTERN
Transmission range: D (Drive the vehicle for 10 seconds or more while the accelerator opening angle is 20% or more)
 
 
PROBABLE CAUSES
  • Malfunction of turbine speed sensor
  • Damaged wiring harness and connectors
  • Malfunction of TCM
 
 
DIAGNOSIS
STEP 1. Check for open circuit in ground line between the turbine speed sensor connector (terminal No. 3) and the body ground
Is the check result normal?
Go to Step 2.
Repair the connector(s) or the wiring harness.
 
STEP 2. Voltage measurement at turbine speed sensor connector (terminal No. 1)
(1) Disconnect the turbine speed sensor connector, and measure at the wiring harness side.
(2) Turn the ignition switch to the "ON" position.
(3) Measure the voltage between the turbine speed sensor connector (terminal No. 1) and body ground.
OK: 10 V or more
Is the check result normal?
Go to Step 3.
Repair the connector(s) or the wiring harness (power supply line between the turbine speed sensor connector terminal No. 1 and the CVT control relay connector).
 
STEP 3. Check for open circuit or short to ground in TRBS line between the turbine speed sensor connector and the TCM connector
Is the check result normal?
Go to Step 4.
Repair the connector(s) or the wiring harness.
 
STEP 4. Measure the output wave pattern of the turbine speed sensor at TCM connector (TRBS terminal).
(1) Connect the turbine speed sensor connector and TCM connector.
(2) Selector lever position: L
(3) Drive at a constant speed of approx. 20 km/h (13 mph).
(4) Connect an oscilloscope, and measure the voltage between TCM connector TRBS terminal and body ground.
OK: A wave pattern such as the one shown on (Check Procedure Using an Oscilloscope) should be output. There should be no noise in the output wave pattern.
Is the check result normal?
Go to Step 5.
Visually check the tip of the sensor for deposits or damage, and repair or replace the turbine speed sensor if necessary.
 
STEP 5. Symptom recheck after erasing diagnostic trouble code
Is the diagnostic trouble code set?
Replace the TCM.
Intermittent malfunction (Refer to GROUP 00 - How to Cope with Intermittent Malfunctions ).