STARTER RELAY CONTINUITY CHECK
Battery voltage
Terminal number to be connected to tester
Continuity test results
Not applied
4 - 3
Open circuit
Connect terminal number 2 and battery (+) terminal.
Connect terminal number 1 and battery (-) terminal.
4 - 3
Continuity (Less than 2 ohms)