ACCURACY CHECK OF OCCUPANT CLASSIFICATION SENSOR
 
 
Required Special Tools:
  • MB991958: Scan Tool (M.U.T.-III Sub Assembly)
    • MB991824: Vehicle Communication Interface(V.C.I.)
    • MB991827: M.U.T.-III USB Cable
    • MB991910: M.U.T.-III Main Harness A
cautionThe following precaution must be observed when executing accuracy testing and calibration.
  • Perform the occupant classification sensor calibration at room temperature. (Proposal: 20 ± 15°C (68 ± 27° F)) (Before the calibration, place the occupant classification sensor more than 30 minutes at room temperature.)
  • Do not apply any load or vibration while the weight check and the calibration is performed.
  • Perform the weight check and the calibration after seat components are all assembled.
1.
cautionTo prevent damage to scan tool MB991958, always turn the ignition switch to the "LOCK" (OFF) position before connecting or disconnecting scan tool MB991958.
Connect scan tool MB991958 to the data link connector.

2. To execute accuracy check and calibration, operate scan tool MB991958 (M.U.T.-III Sub Assembly) as follows.
(1) Select "OCM".
(2) Select "Special Function".
(3) Select "Zero Calibration & System Test".
(4) The start of the zero calibration.
(5) The execution check of the zero calibration.
(6) The zero calibration has been completed when the screen as shown in the illustration is displayed. The OK button is pushed and it progresses to the next.
(7) The start of 66 lbs system test.
(8) The execution check of the 66 lbs system test.
(9) The 66 lbs system test has been completed when the screen as shown in the illustration is displayed. The OK button is pushed and it progresses to the next.
(10) The start of 0 lbs system test.
(11) The execution check of the 0 lbs system test.
(12) The 0 lbs system test has been completed when the screen as shown in the illustration is displayed.