[Previous][Next]
INSPECTION <VEHICLES WITH HEATED SEAT>
 
 
SEAT CUSHION HEATER INSPECTION
Measure the resistance between terminals.
Standard value: At room temperature 20 °C
 
Tester connectionSpecified condition
Seat cushion heater terminal No.1 - seatback heater terminal No.10.198 - 0.242 Ω
Seat cushion heater terminal No.3 - seatback heater terminal No.14.13 - 5.03 Ω <Thermostat: ON>
3.93 - 4.79 Ω <Thermostat: OFF>
 
 
 
SEATBACK HEATER INSPECTION
Measure the resistance between the terminals.
Standard value (interior temperature: 20 °C):
 
Terminal numberStandard value
1 - 25.11 - 6.23 Ω
 
 
 
HEATED SEAT RELAY CONTINUITY CHECK
 
Battery voltageTester connectionSpecified condition
Not applied3 - 4Open circuit
  • Connect terminal 2 to the positive battery terminal
  • Connect terminal 1 to the negative battery terminal
3 - 4Continuity exists (2Ω or less)