[Previous][Next]
REMOVAL AND INSTALLATION
 
 
Blower motor removal steps
Bottom cover assembly (passenger's side) (Refer to GROUP 52A - Instrument Panel ).
1.Blower motor
 
 
Air mixing damper control motor, mode selection damper control motor removal steps
Foot duct (Refer to ).
<<A>>2.Air mixing damper control motor (driver’s side)
<<A>>3.Air mixing damper control motor (passenger's side)
<<A>>4.Mode selection damper control motor
 
 
Clean air filter removal steps
Glove box, Globe box assembly (Refer to GROUP 52A - Instrument Panel ).
5.Clean air filter cover
>>B<<6.Clean air filter
Outside/inside air selection damper control motor removal steps
Glove box, Globe box assembly (Refer to GROUP 52A - Instrument Panel ).
<<A>>>>A<<7.Outside/inside air selection damper control motor
 
 
REMOVAL SERVICE POINT
 
 
<<A>> AIR MIXING DAMPER CONTROL MOTOR, OUTSIDE/INSIDE AIR SELECTION DAMPER CONTROL MOTOR, MODE SELECTION DAMPER CONTROL MOTOR REMOVAL
noteA normal plate-type ratchet driver is recommended.
 
 
 
 
INSTALLATION SERVICE POINT
 
 
>>A<< OUTSIDE/INSIDE AIR SELECTION DAMPER CONTROL MOTOR INSTALLATION
Install the outside/inside air selection damper control motor while pressing the outside/inside air selection damper from the hole of the blower motor.
 
 
 
>>B<< CLEAN AIR FILTER INSTALLATION
Install the clean air filter in the direction shown.