[Previous][Next]
Inspection Procedure 3: POWER Indicator is not Lit (Normal Charging is Impossible).
 
 
 
 
COMMENTS ON TROUBLE SYMPTOM
When the charging cable is connected with electrical outlets, the POWER indicator should be lit. If the POWER indicator is not lit, the AC power supply (supply side) or the charging cable may be failed.
 
 
 
PROBABLE CAUSES
  • The AC power supply (supply side) is failed.
  • The charging cable is failed.
 
 
 
DIAGNOSIS
Required Special Tools
  • MB991223: Wiring harness set
  • MB992006: Extra fine probe
STEP 1. Check the trouble symptom
  • Connect the charging cable with electrical outlets. At that time, check that the POWER indicator is lit, also the CHARGING indicator and the FAULT indicator are momentarily lit.
Does the trouble symptom persist?
Replace the charging cable.
Check the AC power supply usage conditions used by the users.