[Previous][Next]
Inspection Procedure 2: Although Normal Charging is Possible, POWER Indicator and CHARGING Indicator are not Lit.
 
 
 
 
COMMENTS ON TROUBLE SYMPTOM
If the POWER indicator and the CHARGING indicator are not lit although the normal charging is enabled, the indicator circuit may be failed.
 
 
 
PROBABLE CAUSE
  • The charging cable is failed.
 
 
 
 
DIAGNOSIS
Required Special Tools
  • MB991223: Wiring harness set
  • MB992006: Extra fine probe
STEP 1. Check the trouble symptom
  • Connect the charging cable with home sockets. At that time, check that the POWER indicator is lit, also the CHARGING indicator and the FAULT indicator are momentarily lit.
Does the trouble symptom persist?
Replace the charging cable.
Intermittent malfunction (Refer to GROUP 00 - How to Use Troubleshooting/Inspection Service Points - How to Cope with Intermittent Malfunctions ).