1 | Module voltage | Power supply mode of electric motor switch is ON | Terminal voltage (V) of main drive lithium-ion battery module |
2 | Cell total voltage | Power supply mode of electric motor switch is ON | Sum of voltage (V) of each battery cell composing main drive lithium-ion battery module |
3 | Voltage diff. (Module - Total cell) | Power supply mode of electric motor switch is ON | Difference between sum of battery cell voltage and module voltage |
4 | Cell 01 voltage | Power supply mode of electric motor switch is ON | Battery cell voltage (V) |
5 | Cell 02 voltage | Power supply mode of electric motor switch is ON | Battery cell voltage (V) |
6 | Cell 03 voltage | Power supply mode of electric motor switch is ON | Battery cell voltage (V) |
7 | Cell 04 voltage | Power supply mode of electric motor switch is ON | Battery cell voltage (V) |
8 | Cell 05 voltage | Power supply mode of electric motor switch is ON | Battery cell voltage (V) |
9 | Cell 06 voltage | Power supply mode of electric motor switch is ON | Battery cell voltage (V) |
10 | Cell 07 voltage | Power supply mode of electric motor switch is ON | Battery cell voltage (V) |
11 | Cell 08 voltage | Power supply mode of electric motor switch is ON | Battery cell voltage (V) |
22 | Cell monitor IC 1 | Power supply mode of electric motor switch is ON | Normal |
23 | Cell monitor IC 2 | Power supply mode of electric motor switch is ON | Normal |
24 | Cell monitor IC 3 | Power supply mode of electric motor switch is ON | Normal |
25 | Cell monitor IC 4 | Power supply mode of electric motor switch is ON | Normal |
26 | Cell monitor IC 5 | Power supply mode of electric motor switch is ON | Normal |
27 | Cell monitor IC 6 | Power supply mode of electric motor switch is ON | Normal |
28 | Voltage sensor | Power supply mode of electric motor switch is ON | Normal |
29 | Microcomputer reference voltage | Power supply mode of electric motor switch is ON | Normal |
30 | IC reference voltage | Power supply mode of electric motor switch is ON | Normal |
31 | Temperature sensor 1 (open) | Power supply mode of electric motor switch is ON | Normal |
32 | Temperature sensor 2 (open) | Power supply mode of electric motor switch is ON | Normal |
33 | Temperature sensor 3 (open) | Power supply mode of electric motor switch is ON | Normal |
34 | Temperature sensor 4 (open) | Power supply mode of electric motor switch is ON | Normal |
35 | Temperature sensor 5 (open) | Power supply mode of electric motor switch is ON | Normal |
37 | Temperature sensor 1 (short) | Power supply mode of electric motor switch is ON | Normal |
38 | Temperature sensor 2 (short) | Power supply mode of electric motor switch is ON | Normal |
39 | Temperature sensor 3 (short) | Power supply mode of electric motor switch is ON | Normal |
40 | Temperature sensor 4 (short) | Power supply mode of electric motor switch is ON | Normal |
41 | Temperature sensor 5 (short) | Power supply mode of electric motor switch is ON | Normal |
43 | Cell 01 voltage underflow | Power supply mode of electric motor switch is ON | Normal |
44 | Cell 02 voltage underflow | Power supply mode of electric motor switch is ON | Normal |
45 | Cell 03 voltage underflow | Power supply mode of electric motor switch is ON | Normal |
46 | Cell 04 voltage underflow | Power supply mode of electric motor switch is ON | Normal |
47 | Cell 05 voltage underflow | Power supply mode of electric motor switch is ON | Normal |
48 | Cell 06 voltage underflow | Power supply mode of electric motor switch is ON | Normal |
49 | Cell 07 voltage underflow | Power supply mode of electric motor switch is ON | Normal |
50 | Cell 08 voltage underflow | Power supply mode of electric motor switch is ON | Normal |
55 | Cell 01 voltage overflow | Power supply mode of electric motor switch is ON | Normal |
56 | Cell 02 voltage overflow | Power supply mode of electric motor switch is ON | Normal |
57 | Cell 03 voltage overflow | Power supply mode of electric motor switch is ON | Normal |
58 | Cell 04 voltage overflow | Power supply mode of electric motor switch is ON | Normal |
59 | Cell 05 voltage overflow | Power supply mode of electric motor switch is ON | Normal |
60 | Cell 06 voltage overflow | Power supply mode of electric motor switch is ON | Normal |
61 | Cell 07 voltage overflow | Power supply mode of electric motor switch is ON | Normal |
62 | Cell 08 voltage overflow | Power supply mode of electric motor switch is ON | Normal |
67 | Temperature sensor 1 underflow | Power supply mode of electric motor switch is ON | Normal |
68 | Temperature sensor 2 underflow | Power supply mode of electric motor switch is ON | Normal |
69 | Temperature sensor 3 underflow | Power supply mode of electric motor switch is ON | Normal |
70 | Temperature sensor 4 underflow | Power supply mode of electric motor switch is ON | Normal |
71 | Temperature sensor 5 underflow | Power supply mode of electric motor switch is ON | Normal |
73 | Temperature sensor 1 overflow | Power supply mode of electric motor switch is ON | Normal |
74 | Temperature sensor 2 overflow | Power supply mode of electric motor switch is ON | Normal |
75 | Temperature sensor 3 overflow | Power supply mode of electric motor switch is ON | Normal |
76 | Temperature sensor 4 overflow | Power supply mode of electric motor switch is ON | Normal |
77 | Temperature sensor 5 overflow | Power supply mode of electric motor switch is ON | Normal |
79 | EEPROM Fail (Numbering data read) | Power supply mode of electric motor switch is ON | Normal |
80 | EEPROM Fail (Learning data read) | Power supply mode of electric motor switch is ON | Normal |
81 | CAN controller | Power supply mode of electric motor switch is ON | Normal |
82 | Cell 01 connection terminal | Power supply mode of electric motor switch is ON | Normal |
83 | Cell 03 connection terminal | Power supply mode of electric motor switch is ON | Normal |
84 | Cell 05 connection terminal | Power supply mode of electric motor switch is ON | Normal |
85 | Cell 07 connection terminal | Power supply mode of electric motor switch is ON | Normal |
88 | A/D conversion (Reference VOLT.) | Power supply mode of electric motor switch is ON | Normal |
89 | A/D conversion (Temp. sensor 1) | Power supply mode of electric motor switch is ON | Normal |
90 | A/D conversion (Temp. sensor 2) | Power supply mode of electric motor switch is ON | Normal |
91 | A/D conversion (Temp. sensor 3) | Power supply mode of electric motor switch is ON | Normal |
92 | A/D conversion (Temp. sensor 4) | Power supply mode of electric motor switch is ON | Normal |
93 | A/D conversion (Temp. sensor 5) | Power supply mode of electric motor switch is ON | Normal |
95 | A/D conversion (Module voltage) | Power supply mode of electric motor switch is ON | Normal |
96 | Balancer drive time fail (20h) | Power supply mode of electric motor switch is ON | Normal |
97 | EEPROM Fail (failure info. read) | Power supply mode of electric motor switch is ON | Normal |
98 | Bat-CAN (Bus off) | Power supply mode of electric motor switch is ON | Normal |