[Previous][Next]
CMU DATA LIST REFERENCE TABLE
 
 
noteThere are 10 CMUs from the CMU 01 to the CMU 05 and the CMU 07 to the CMU 11. The service data of each CMU can be checked.
Item No.Inspection itemInspection conditionsNormal value judgment
1Module voltagePower supply mode of electric motor switch is ONTerminal voltage (V) of main drive lithium-ion battery module
2Cell total voltagePower supply mode of electric motor switch is ONSum of voltage (V) of each battery cell composing main drive lithium-ion battery module
3Voltage diff. (Module - Total cell)Power supply mode of electric motor switch is ONDifference between sum of battery cell voltage and module voltage
4Cell 01 voltagePower supply mode of electric motor switch is ONBattery cell voltage (V)
5Cell 02 voltagePower supply mode of electric motor switch is ONBattery cell voltage (V)
6Cell 03 voltagePower supply mode of electric motor switch is ONBattery cell voltage (V)
7Cell 04 voltagePower supply mode of electric motor switch is ONBattery cell voltage (V)
8Cell 05 voltagePower supply mode of electric motor switch is ONBattery cell voltage (V)
9Cell 06 voltagePower supply mode of electric motor switch is ONBattery cell voltage (V)
10Cell 07 voltagePower supply mode of electric motor switch is ONBattery cell voltage (V)
11Cell 08 voltagePower supply mode of electric motor switch is ONBattery cell voltage (V)
22Cell monitor IC 1Power supply mode of electric motor switch is ONNormal
23Cell monitor IC 2Power supply mode of electric motor switch is ONNormal
24Cell monitor IC 3Power supply mode of electric motor switch is ONNormal
25Cell monitor IC 4Power supply mode of electric motor switch is ONNormal
26Cell monitor IC 5Power supply mode of electric motor switch is ONNormal
27Cell monitor IC 6Power supply mode of electric motor switch is ONNormal
28Voltage sensorPower supply mode of electric motor switch is ONNormal
29Microcomputer reference voltagePower supply mode of electric motor switch is ONNormal
30IC reference voltagePower supply mode of electric motor switch is ONNormal
31Temperature sensor 1 (open)Power supply mode of electric motor switch is ONNormal
32Temperature sensor 2 (open)Power supply mode of electric motor switch is ONNormal
33Temperature sensor 3 (open)Power supply mode of electric motor switch is ONNormal
34Temperature sensor 4 (open)Power supply mode of electric motor switch is ONNormal
35Temperature sensor 5 (open)Power supply mode of electric motor switch is ONNormal
37Temperature sensor 1 (short)Power supply mode of electric motor switch is ONNormal
38Temperature sensor 2 (short)Power supply mode of electric motor switch is ONNormal
39Temperature sensor 3 (short)Power supply mode of electric motor switch is ONNormal
40Temperature sensor 4 (short)Power supply mode of electric motor switch is ONNormal
41Temperature sensor 5 (short)Power supply mode of electric motor switch is ONNormal
43Cell 01 voltage underflowPower supply mode of electric motor switch is ONNormal
44Cell 02 voltage underflowPower supply mode of electric motor switch is ONNormal
45Cell 03 voltage underflowPower supply mode of electric motor switch is ONNormal
46Cell 04 voltage underflowPower supply mode of electric motor switch is ONNormal
47Cell 05 voltage underflowPower supply mode of electric motor switch is ONNormal
48Cell 06 voltage underflowPower supply mode of electric motor switch is ONNormal
49Cell 07 voltage underflowPower supply mode of electric motor switch is ONNormal
50Cell 08 voltage underflowPower supply mode of electric motor switch is ONNormal
55Cell 01 voltage overflowPower supply mode of electric motor switch is ONNormal
56Cell 02 voltage overflowPower supply mode of electric motor switch is ONNormal
57Cell 03 voltage overflowPower supply mode of electric motor switch is ONNormal
58Cell 04 voltage overflowPower supply mode of electric motor switch is ONNormal
59Cell 05 voltage overflowPower supply mode of electric motor switch is ONNormal
60Cell 06 voltage overflowPower supply mode of electric motor switch is ONNormal
61Cell 07 voltage overflowPower supply mode of electric motor switch is ONNormal
62Cell 08 voltage overflowPower supply mode of electric motor switch is ONNormal
67Temperature sensor 1 underflowPower supply mode of electric motor switch is ONNormal
68Temperature sensor 2 underflowPower supply mode of electric motor switch is ONNormal
69Temperature sensor 3 underflowPower supply mode of electric motor switch is ONNormal
70Temperature sensor 4 underflowPower supply mode of electric motor switch is ONNormal
71Temperature sensor 5 underflowPower supply mode of electric motor switch is ONNormal
73Temperature sensor 1 overflowPower supply mode of electric motor switch is ONNormal
74Temperature sensor 2 overflowPower supply mode of electric motor switch is ONNormal
75Temperature sensor 3 overflowPower supply mode of electric motor switch is ONNormal
76Temperature sensor 4 overflowPower supply mode of electric motor switch is ONNormal
77Temperature sensor 5 overflowPower supply mode of electric motor switch is ONNormal
79EEPROM Fail (Numbering data read)Power supply mode of electric motor switch is ONNormal
80EEPROM Fail (Learning data read)Power supply mode of electric motor switch is ONNormal
81CAN controllerPower supply mode of electric motor switch is ONNormal
82Cell 01 connection terminalPower supply mode of electric motor switch is ONNormal
83Cell 03 connection terminalPower supply mode of electric motor switch is ONNormal
84Cell 05 connection terminalPower supply mode of electric motor switch is ONNormal
85Cell 07 connection terminalPower supply mode of electric motor switch is ONNormal
88A/D conversion (Reference VOLT.)Power supply mode of electric motor switch is ONNormal
89A/D conversion (Temp. sensor 1)Power supply mode of electric motor switch is ONNormal
90A/D conversion (Temp. sensor 2)Power supply mode of electric motor switch is ONNormal
91A/D conversion (Temp. sensor 3)Power supply mode of electric motor switch is ONNormal
92A/D conversion (Temp. sensor 4)Power supply mode of electric motor switch is ONNormal
93A/D conversion (Temp. sensor 5)Power supply mode of electric motor switch is ONNormal
95A/D conversion (Module voltage)Power supply mode of electric motor switch is ONNormal
96Balancer drive time fail (20h)Power supply mode of electric motor switch is ONNormal
97EEPROM Fail (failure info. read)Power supply mode of electric motor switch is ONNormal
98Bat-CAN (Bus off)Power supply mode of electric motor switch is ONNormal