DTC P1E0F: Battery pack state of charge stuck
caution
Whenever ECU is replaced, ensure that the CAN bus lines are normal.
MONITOR EXECUTION
Continuous
MONITOR EXECUTION CONDITIONS (Other monitor and Sensor)
Other Monitor (There is no temporary DTC set in memory for the item monitored below)
Not applicable
Sensor (The sensor below is determined to be normal)
Not applicable
DTC SET CONDITIONS
Logic Flow Chart
Check Conditions
battery management unit (BMU) power supply voltage is 8 volts to 16 volts.
Time after above conditions satisfy is more than 2 second.
Judgment Criterion
SOC fault counter is more than 3 time.
FAIL-SAFE AND BACKUP FUNCTION
Not available
PROBABLE CAUSES
The battery management unit (BMU) is failed.
DIAGNOSIS
Replace the battery management unit (BMU) (Refer to
).