STEP 2. Resistance measurement at joint connector (CAN5) and OSS-ECU connector.
caution | A digital multimeter should be used. For details refer to . |
caution | The test wiring harness should be used. For details refer to . |
(1) Disconnect joint connector (CAN5) and the OSS-ECU connector, and measure at the wiring harness side.
(2) Turn off the power supply mode of the electric motor switch.
(3) caution | When measuring the resistance, disconnect the negative 12V starter battery terminal. For details refer to . |
Ensure that the negative 12V starter battery terminal is disconnected.
(4) Continuity between joint connector (CAN5) terminal No.10 and OSS-ECU connector terminal No.1OK: Continuity (2 ohms or less)
(5) Continuity between joint connector (CAN5) terminal No.21 and OSS-ECU connector terminal No.14OK: Continuity (2 ohms or less)
caution | Strictly observe the specified wiring harness repair procedure. For details refer to . |
Is the check result normal?
<All the resistances measure 2 ohms or less> Go to Step 3. : <Either or all of the resistances measure more than 2 ohms> Repair the wiring harness between joint connector (CAN5) and the OSS-ECU connector.