STEP 1. Check the hazard warning light switch.
STEP 2. Resistance measurement at hazard warning light switch connector (ground terminal)
(1) Disconnect the connector, and measure at the wiring harness side.
(2) Measure the resistance between the hazard warning light switch connector (ground terminal) and ground.OK: The resistance should be 2 ohms or less
Is the check result normal?
Go to Step 4. Go to Step 3.
STEP 3. Check of open circuit in ground line between hazard warning light switch connector and ground
STEP 4. Check of short to power supply, short to ground, and open circuit in HAZ line between ETACS-ECU connector and hazard warning light switch connector
STEP 5. Using scan tool (M.U.T.-IIISE), check data list.
(1) caution | To prevent damage to scan tool (M.U.T.-IIISE), always turn off the power supply mode of the electric motor switch before connecting or disconnecting scan tool (M.U.T.-IIISE). |
Connect scan tool (M.U.T.-IIISE). Refer to "How to connect Scan Tool (M.U.T.-IIISE)
."
(2) Check the input signals from the hazard warning light switch.- Turn ON the hazard warning light switch.
| Item No. | Item name | Normal condition | 265 | Hazard switch | ON |
|
OK: Normal condition is displayed.
Is the check result normal?
The trouble can be an intermittent malfunction (Refer to GROUP 00 - How to use Troubleshooting/inspection Service Points - How to Cope with Intermittent Malfunction ). Replace the ETACS-ECU.