STEP 1. Check the installation condition.
STEP 2. Rear door switch (RH) check
STEP 3. Check of short to power supply, short to ground, and open circuit in DRH line between ETACS-ECU connector and rear door switch (RH) connector
STEP 4. Using scan tool (M.U.T.-IIISE), check data list.
(1) caution | To prevent damage to scan tool (M.U.T.-IIISE), always turn off the power supply mode of the electric motor switch before connecting or disconnecting scan tool (M.U.T.-IIISE). |
Connect scan tool (M.U.T.-IIISE). Refer to "How to connect Scan Tool (M.U.T.-IIISE)
."
(2) Open the rear right door. | Item No. | Item name | Normal condition | 258 | RR door ajar switch | Open |
|
OK: Normal condition is displayed.
Is the check result normal?