Inspection Procedure 2: The stoplights do not illuminate or go out normally.
 
 
 
 
TECHNICAL DESCRIPTION (COMMENT)
If the stoplights do not illuminate or go out normally, the stoplight switch input signal circuit, or the stoplights may be defective.
 
 
TROUBLESHOOTING HINTS
  • The stoplight switch input signal circuit may be defective
  • The rear combination light assembly may be defective
  • The high-mounted stoplight may be defective
  • The wiring harness or connectors may have loose, corroded, or damaged terminals, or terminals pushed back in the connector
 
 
DIAGNOSIS
Required Special Tools:
  • MB992006: Extra fine probe
  • MB991223: Harness set
STEP 1. Using scan tool (M.U.T.-IIISE), check data list
(1)
cautionTo prevent damage to scan tool (M.U.T.-IIISE), always turn off the power supply mode of the electric motor switch before connecting or disconnecting scan tool (M.U.T.-IIISE).
Connect scan tool (M.U.T.-IIISE). Refer to "How to connect Scan Tool (M.U.T.-IIISE) ."
(2) Check the input signals from the stoplight switch.
  • Brake pedal: depressed
 
Item No.Item nameNormal condition
Item 290stoplight switchON
OK: Normal condition is displayed.
Is the check result normal?
Go to Step 2.
Troubleshoot the ETACS-ECU. Refer to Inspection Procedure 11 "The stoplight switch signal is not received."
 
STEP 2. Check the rear combination light socket
Check the continuity at the rear combination light socket to confirm whether it is normal.
Is the check result normal?
Go to Step 3.
Replace the rear combination light socket.
 
STEP 3. Resistance measurement at the stoplight connectors (ground terminals).
(1) Disconnect the connector, and measure at the wiring harness side.
(2) Measure the resistance between the rear combination light (stoplight: LH) connector (ground terminal) and ground.
(3) Measure the resistance between the rear combination light (stoplight: RH) connector (ground terminal) and ground.
(4) Measure the resistance between the high-mounted stoplight connector (ground terminal) and ground.
OK: The resistance should be 2 ohms or less
Is the check result normal?
The trouble can be an intermittent malfunction (Refer to GROUP 00 - How to use Troubleshooting/inspection Service Points - How to Cope with Intermittent Malfunction ).
Go to Step 4.
 
STEP 4. Check of open circuit in ground line between the rear combination light (stoplight: LH) connector, rear combination light (stoplight: RH) connector, high-mounted stoplight connector and ground.
Is the check result normal?
Go to Step 5.
Repair the connector(s) or wiring harness.
 
STEP 5. Check of short to power supply, short to ground, and open circuit in STLO line between ETACS-ECU connector and rear combination light (stoplight: LH) connector, rear combination light (stoplight: RH) connector, high-mounted stoplight connector.
Is the check result normal?
Go to Step 6.
Repair the connector(s) or wiring harness.
 
STEP 6. Retest the system
Check that the stoplights illuminates normally.
Is the check result normal?
: The trouble can be an intermittent malfunction (Refer to GROUP 00 - How to use Troubleshooting/inspection Service Points - How to Cope with Intermittent Malfunction ).
: Replace the high-mounted stoplight.
: Replace the rear combination light assembly (LH) or (RH).