[Previous][Next]
Calibration
 
 
Calibrate according to the procedure below after the following operation is performed:
  • Replacement of the camera-ECU
  • Removal and installation/replacement of a camera
  • Any of the door or the liftgate, Outside rear-view mirror assembly (LH), (RH) is aligned.
  • The front bumper center cover is deformed or loosened due to a collision accident.
 
 
How to check the image screen visually
 
 
Checking image from the front view camera
1. Draw white 10 cm (3.9 inches)-wide lines next to either side of the vehicle.
2. Press the camera switch on the steering wheel remote control switch (LH) to display the bird's eye-view on the multivision display.
3. Two white lines should be displayed as "straight line". When the line is broken or offset, calibrate the cameras.
 

 
 
Checking image from the rear view camera
1. Draw white 10 cm (3.9 inches)-wide lines next to either side of the vehicle.
2. Press the camera switch on the steering wheel remote control switch (LH) to display the bird's eye-view on the multivision display.
3. Two white lines should be displayed as "straight line". When the line is broken or offset, calibrate the cameras.
 

 
 
Checking image from the side view camera (RH)
noteThe left side camera must be also calibrated.
1. Draw white 10 cm (3.9 inches)-wide lines next to the right side of the vehicle.
2. Press the camera switch on the steering wheel remote control switch (LH) to display the bird's eye-view on the multivision display.
3. Two white lines should be displayed as "straight line". When the line is broken or offset, calibrate the cameras.
 
 
 
 
How to write learned value to the camera-ECU
When the camera is replaced, write a learned value to the new camera-ECU according to the procedure below.
1.
cautionTo prevent damage to scan tool (M.U.T.-IIISE), always turn off the power supply mode of the electric motor switch before connecting or disconnecting scan tool (M.U.T.-IIISE).
Connect scan tool (M.U.T.-IIISE) to the data link connector. Refer to "How to connect the Scan Tool (M.U.T.-IIISE) ."
2. Select "Write learned value(Changed ECU)" and then "Learned value Read & save" in the special functions for the multi-around monitor system to save the learned value, which is stored in the current camera-ECU, to the scan tool (M.U.T.-IIISE).
noteIf the learned value cannot be read, replace the camera-ECU and then calibrate the camera.
3. Replace the camera-ECU (Refer to ).
4. Select "Write learned value(Changed ECU)" and then "Saved learned value writing" in the special functions to write the learned value, which is stored in the scan tool (M.U.T.-IIISE), to the camera-ECU.
5. If any problems are not found on the screen, the calibration is complete. If any problem is found, calibrate the camera.
 
 
 
How to calibrate a camera
Required Special Tool:
  • MB993003: Calibration marker
caution
  • Do not interrupt a camera vision range while a camera-ECU is calibrated.
  • Before the calibration, make sure that no drops of water or dirt are adhered to the respective camera lens. If yes, an incorrect calibration may be caused. Wipe it off with a damp cloth, then wipe again with a dry cloth.
1. When the camera-ECU is replaced, first write a learned value to the camera-ECU.
2. Park the vehicle on a level surface.
notePrevent sun light rays from interfering with the camera, otherwise the monitor screen will be reflected in white. Ideally, the brightness of a road surface should be low (such as black).
3. One person should sit on the driver's seat.
4.
cautionTo prevent damage to scan tool (M.U.T.-IIISE), always turn off the power supply mode of the electric motor switch before connecting or disconnecting scan tool (M.U.T.-IIISE).
Connect scan tool (M.U.T.-IIISE) to the data link connector. Refer to "How to connect the Scan Tool (M.U.T.-IIISE) ."
5. Position the calibration markers (MB993003) as shown.
  • Position the calibration markers in respect to the relevant camera only.
note
  • The calibration markers should be located in the permissible range. The range is within ± 3 cm (1.2 inches) and 1 degree from the standard position.
6. Turn "ON → OFF → ON" the electric motor switch position.
7. Use the scan tool (M.U.T.-IIISE) to calibrate the camera.
noteWhen you execute the calibration, all calibration-related data will be erased from the ECU.
8. Select "Calibration" in the "special function" for the multi-around monitor system.
9. Select a camera to be calibrated on the data list located to the left of the calibration screen, and then press "OK."
 
Item No.Item nameContents
1Front cameraCalibrate only the selected camera.
2Rear camera
3Left side camera
4Right side camera
10. Select the camera being calibrated in the confirmation screen, and the press "OK."
11. Press the "OK" button after the execution screen is displayed.
12. When the calibration has completed successfully, "Completed" will be displayed on the data list item No.13.
13. If the calibration has failed, "Error" will be displayed on the data list item No.13. For details of errors, refer to "Calibration error table."
14. If any problems are not found on the screen, the calibration is complete. If any problems are found, repeat the calibration.
 
 
Calibration error table
Item No.Item nameError contentsTroubleshooting
14Coding not comp/Setting err.flagThe variant coding for the ETACS-ECU has not been implemented.Check whether DTC No. U1195 is set. If yes, diagnose the system according to the DTC.
Requirements for the calibration are not satisfied.Check whether the requirements for the calibration are satisfied.
  • Are the calibration markers positioned correctly?
  • Is a strong illumination, which a camera misinterprets as a white line on the calibration marker, emitted nearby?
15Door open detection flagAny of the doors and liftgate are open.Check that any of the doors and liftgate are closed. If no, close the door or the liftgate.
16Front camera error flagThe front-view camera does not recognize either of the calibration markers precisely.
  1. Check the vehicle conditions.
    • Are prerequisites for the calibration satisfied?
    • Is the vehicle parked in a correct position?
    • Is the camera lens contaminated?
  2. Check the calibration markers.
    • Are the calibration markers positioned correctly?
    • Are the calibration markers contaminated?
    • Is any of the calibration markers hard to see due to a sunlight refection?
  3. Repeat the calibration.
17Rear camera error flagThe rear-view camera does not recognize either of the calibration markers precisely.
18Left side camera error flagThe side-view camera (LH) does not recognize either of the calibration markers precisely.
19Right side camera error flagThe side-view camera (RH) does not recognize either of the calibration markers precisely.
20Flash ROM writing error flagInternal malfunction of camera-ECU.
  1. Repeat the calibration.
  2. If any error code is displayed again, replace the camera-ECU (Refer to ).
  3. Repeat the calibration.
21SD-RAM error flag
22EEPROM writing error flag