[Previous][Next]
BLIND SPOT WARNING SWITCH INSPECTION
 
 
ON/OFF CHECK
 
Switch positionTester connectionSpecified condition
ON (switch pushed)11 - 14Continuity exists (2 ohms or less)
OFF (switch released)No continuity
 
 
 
ILLUMINATION CHECK
 
Battery voltageTester connectionSpecified condition
At no energization12 (+) - 13 (-)Not illuminated
With current supplyIlluminated