1. Remove the fuel pump and gauge assembly (Refer to GROUP 13B - On-vehicle Service, Fuel Pump and Gauge Assembly Replacement ).
2. When float of the fuel level sensor is in stopper positions "F" and "E", ensure that resistance between the fuel level sensor terminal and ground terminal is within the standard value.
Standard value:
Float position
Gauge resistance value (ohms)
Stopper position "F"
13.0 ± 1.0
Stopper position "E"
120.0 ± 1.0
When the float is moved slowly between stopper positions "F" and "E", ensure that the resistance is smoothly changing.
FUEL LEVEL SENSOR FLOAT HEIGHT
1. Remove the fuel pump and gauge assembly (Refer to GROUP 13B - On-vehicle Service, Fuel Pump and Gauge Assembly Replacement ).
2. When float is moved to contact the float arm on the stopper, ensure that stopper positions "F" and "E" are within the standard value.