[Previous][Next]
DTC B1135: Electric motor switch
 
 
cautionWhen replacing the ECU, always check that the communication circuit is normal.
 
 
DIAGNOSTIC FUNCTION
When an abnormality is detected for 3 seconds or more with either of the SW1 or SW2 of electric motor switch, OSS-ECU stores DTC B1135, and displays the power supply system error warning screen to the multi information display of the combination meter.
 
 
DTC SET CONDITION
Check Conditions
  • After OSS-ECU activation
Judgment Criterion
  • 3 seconds or more have elapsed since the unmatch between the SW1 and SW2 of electric motor switch is detected
 
 
TROUBLESHOOTING HINTS
  • Electric motor switch malfunction (ON/OFF seizure of SW1 or SW2)
  • Damaged wiring harness or connector (short to power supply, short to ground, or open circuit in SW1 or SW2 line)
  • Malfunction of OSS-ECU
 
 
DIAGNOSIS
Required Special Tools:
  • MB991223: Harness Set
  • MB992006: Extra Fine Probe
STEP 1. Electric motor switch check
Refer to .
Is the check result normal?
Go to Step 2.
Replace the electric motor switch.
 
STEP 2. Using scan tool (M.U.T.-IIISE), check data list.
(1)
cautionTo prevent damage to scan tool (M.U.T.-IIISE), always turn the power supply mode of the electric motor switch to the OFF before connecting or disconnecting scan tool (M.U.T.-IIISE).
Connect scan tool (M.U.T.-IIISE). Refer to "How to connect the Scan Tool (M.U.T.-IIISE) ."
(2) Turn the power supply mode of the electric motor switch to OFF.
(3) Check the OSS-ECU data list.
  • Operate the electric motor switch.
 
Operation stateItem No.Check itemDisplay
When the electric motor switch is pressed1Engine switch/Power switch (1)ON
2Engine switch/Power switch (2)ON
When the electric motor switch is not pressed1Engine switch/Power switch (1)OFF
2Engine switch/Power switch (2)OFF
OK: Operation state and data list display agree with each other.
Are the check result normal?
: Go to Step 5.
: Go to Step 3.
: Go to Step 4.
 
STEP 3. Check of short to power supply, short to ground, and open circuit in SW1 line between OSS-ECU connector and electric motor switch connector
Is the check result normal?
Go to Step 5.
Repair the connector(s) or wiring harness.
 
STEP 4. Check of short to power supply, short to ground, and open circuit in SW2 line between OSS-ECU connector and electric motor switch connector
noteBecause the conformity cannot be determined even when the digital tester is used to measure the voltage of SW2 line between the OSS-ECU connector and electric motor switch connector, be sure to use the oscilloscope. (Outputs the sawtooth waveform of 0 to 5 V with intervals of 10 ms.)
Is the check result normal?
Go to Step 5.
Repair the connector(s) or wiring harness.
 
STEP 5. Recheck for diagnostic trouble code.
(1) Erase the DTC.
(2) Turn the power supply mode of the electric motor switch from OFF to ON.
(3) Check if DTC is set.
(4) Turn the power supply mode of the electric motor switch from ON to OFF.
Is the DTC set?
Replace the OSS-ECU and register the VIN (Refer to ).
Intermittent malfunction is suspected (Refer to GROUP 00 - How to Use Troubleshooting/Inspection Service Points - How to Cope with Intermittent Malfunction ).