Inspection Procedure 1: Cannot communicate with KOS-ECU using the scan tool.
 
 
cautionWhen replacing the ECU, always check that the communication circuit is normal.
 
 
TECHNICAL DESCRIPTION (COMMENT)
KOS-ECU is communicating with scan tool via CAN. Therefore, communication error of KOS-ECU is suspected.
 
 
TROUBLESHOOTING HINTS
  • Malfunction of the power supply and the ground of KOS-ECU
  • Malfunction of CAN bus line
 
 
DIAGNOSIS
1. Using scan tool (M.U.T.-IIISE), diagnose the CAN bus line.
2. Check the power supply circuit and the ground circuit to KOS-ECU.
Refer to Inspection Procedure 3 "Abnormality in KOS-ECU power supply and ground circuits" .
3. Retest the system.