G AND YAW RATE SENSOR CALIBRATION
cautionBefore performing calibration, check that the G and yaw rate sensor-related diagnostic trouble code is not set.
cautionAfter the next operation has been completed, carry out the calibration to make ASC-ECU learn the neutral position of the G and yaw rate sensor.
  • ASC-ECU replacement
1. Park the vehicle on a level surface.
2.
cautionBefore connecting or disconnecting the scan tool (M.U.T.-IIISE), turn off the power supply mode of the electric motor switch.
Before setting scan tool (M.U.T.-IIISE), turn off the power supply mode of the electric motor switch.
3. Turn on the power supply mode of the electric motor switch.
4. Select "ABS/ASC/ASTC/WSS."
5. Select "Special function."
6. Select "Sensor calibration."
7. Select "Lateral G sensor calibration."
8. Select "G sensor calibration."
9. Before removing scan tool (M.U.T.-IIISE) from the vehicle, turn off the power supply mode of the electric motor switch.