INSPECTION
ELECTRICAL PARKING ACTUATOR CHECK
Observe the table below to check the electrical parking actuator. If defective, replace the electrical parking actuator.
Item
Terminal number
Resistance value
Motor U phase
4 - 5
1.25 ± 0.15 Ω [fluid temperature: 20°C (68°F)]
Motor W phase
4 - 9
Motor V phase
4 - 10
note
If you operated electric motor switch, the selector lever or the electrical parking switch, wait for at least five minutes before this measurement.