[Previous][Next]
REMOVAL AND INSTALLATION
 
 
caution
  • When removing or installing the mass airflow sensor, be careful not to apply impact to the sensor.
  • Do not reuse the mass airflow sensor that has been dropped.
Removal steps
>>A<<1.Mass airflow sensor
>>A<<2.O-ring
3.Breather hose connection
4.Air cleaner intake hose
5.Air cleaner intake duct
6.Air cleaner assembly (element, cover, body)
7.Air cleaner cover
8.Air cleaner element
9.Air cleaner body
10.Air cleaner bracket A
11.Air cleaner bracket B
 
 
INSTALLATION SERVICE POINT
 
 
>>A<< O-RING/MASS AIRFLOW SENSOR INSTALLATION
1. Install the mass airflow sensor to the air cleaner cover with care not to damage the O-ring.
2.
cautionDo not over-tighten. If the mounting screw is over-tightened, the air cleaner cover can be damaged.
Tighten the mounting screws to the specified torque.
Tightening torque: 1.5 ± 0.3 N·m (13 ± 2 in-lb)