COOLING FAN RELAY CONTINUITY CHECK
FAN CONTROL RELAY CHECK
Battery voltage
Terminal No. to be connected to tester
Continuity test results
Not applied
2 - 4
Continuity (Less than 2 Ω)
2 - 5
Open circuit
Connect terminal No. 1 and battery (+) terminal.
Connect terminal No. 3 and battery (-) terminal.
2 - 4
Open circuit
2 - 5
Continuity (Less than 2 Ω)
RADIATOR FAN RELAY CHECK
Battery voltage
Terminal No. to be connected to tester
Continuity test results
Not applied
2 - 4
Open circuit
Connect terminal No. 3 and battery (+) terminal.
Connect terminal No. 1 and battery (-) terminal.
Continuity (Less than 2 Ω)
CONDENSER FAN RELAY CHECK
Battery voltage
Terminal No. to be connected to tester
Continuity test results
Not applied
2 - 4
Open circuit
Connect terminal No.3 and battery (+) terminal.
Connect terminal No.1 and battery (-) terminal.
Continuity (Less than 2 Ω)