[Previous][Next]
COOLING FAN RELAY CONTINUITY CHECK
 
 
 
 
FAN CONTROL RELAY CHECK
 
Battery voltageTerminal No. to be connected to testerContinuity test results
Not applied2 - 4Continuity (Less than 2 Ω)
2 - 5Open circuit
Connect terminal No. 1 and battery (+) terminal.
Connect terminal No. 3 and battery (-) terminal.
2 - 4Open circuit
2 - 5Continuity (Less than 2 Ω)
 

 
 
RADIATOR FAN RELAY CHECK
 
Battery voltageTerminal No. to be connected to testerContinuity test results
Not applied2 - 4Open circuit
Connect terminal No. 3 and battery (+) terminal.
Connect terminal No. 1 and battery (-) terminal.
Continuity (Less than 2 Ω)
 

 
 
CONDENSER FAN RELAY CHECK
 
Battery voltageTerminal No. to be connected to testerContinuity test results
Not applied2 - 4Open circuit
Connect terminal No.3 and battery (+) terminal.
Connect terminal No.1 and battery (-) terminal.
Continuity (Less than 2 Ω)