Turn power source | Adjustment of turn-signal light operation condition | ACC or IG1 | Operable with ACC or ON position |
IG1 | Operable with ON position (initial condition) |
Comfort flasher | With/without comfort flasher function | Disable | No function |
Enable | With function (initial condition) |
Hazard answer back | Adjustment of the number of keyless hazard warning light answer back flashes | Lock: 1, Unlock: 2 | LOCK: Flashes once, UNLOCK: Flashes twice (initial condition) |
Lock: 1, Unlock: 0 | LOCK: Flashes once, UNLOCK: No flash |
Lock: 0, Unlock: 2 | LOCK: No flash, UNLOCK: Flash twice |
Lock: 2, Unlock: 1 | LOCK: Flash twice, UNLOCK: Flash once |
Lock: 2, Unlock: 0 | LOCK: Flash twice, UNLOCK: No flash |
Lock: 0, Unlock: 1 | LOCK: No flash, UNLOCK: Flash once |
Lock: 0, Unlock: 0 | No function |
Front wiper operation | Adjustment of the intermittent windshield wiper operation | Normal INT | Intermittent wiper interval is fixed to 4 seconds. |
Variable INT | Intermittent wiper interval is calculated only by the wiper volume control. |
Speed Sensitive | Intermittent wiper interval is calculated according to the intermittent wiper volume control and vehicle speed. |
Rain Sensitive | Intermittent wiper interval is calculated according to the intermittent wiper volume control and lighting control sensor (initial condition). |
Front/rear wiper washer | Disabling or enabling washer-linked wiper function | Only Washer | No function |
Washer & Wiper | With function: Without delayed finishing wipe function (Initial condition) |
With after wipe | With function: With delayed finishing wipe function |
Intermittent time of rear wiper | Adjustment of rear wiper interval | 0 sec | No wiper interval |
4 sec | 4 seconds |
8 sec | 8 seconds (initial condition) |
16 sec | 16 seconds |
Rear wiper Low speed mode | Disabling or enabling rear wiper continuous operation | Disable | No function |
Enable | With function (initial condition) |
Auto fold mirror | Electric folding door mirror automatic unfolding function <electric retractable remote controlled door mirrors> | Not Auto | No synchronized operation |
Open Vehicle SPD | Vehicle speed-dependent operation |
Open/Close by IG | Electric motor switch linked operation |
OPN/CLS Keyless | Keyless entry linked operation (initial condition) |
Sensitivity for auto light <Lighting switch with OFF position> | Lighting control sensor sensitivity (illumination intensity) | Level 1 bright | High-high ambient brightness |
Level 2 bright | High ambient brightness |
Level 3 | Standard ambient brightness (initial condition) |
Level 4 dark | Low ambient brightness |
Level 5 dark | Low-low ambient brightness |
Dome light delay timer with door | Adjustment of interior light delay shutdown time | 0 sec | 0 second (no delay shutdown time) |
7.5 sec | 7.5 seconds |
15 sec | 15 seconds |
30 sec | 30 seconds (initial condition) |
60 sec | 60 seconds |
120 sec | 120 seconds |
180 sec | 180 seconds |
Headlight auto cut customize | Adjustment of headlight automatic shutdown function | Disable | No function |
Enable (C-spec.) | With function (initial condition) |
Interior light auto cut timer | Adjustment of interior light automatic shutdown function operation time | Disable | No function |
3 min | 3 minutes |
30 min | 30 minutes (initial condition) |
60 min | 60 minutes |
Auto door unlock | Adjustment of the auto door unlock function | Disable | Without function (initial condition) |
Always (Lock pos) | With function: Operates when the electric motor switch is moved to the LOCK position. |
Door unlock mode | Adjustment of power door locks with selective unlocking | All Doors Unlock | Without function: The first operation of unlock operation by KOS unlocks all doors. |
Dr Door Unlock | With function: The first operation of unlock operation by KOS unlocks the driver's door only, and the second unlock operation within 2 seconds after that unlocks all doors. (initial condition) |
Horn chirp by keyless | Horn chirp by keyless entry system | Not sound horn | No horn answerback function |
Lock any time | The horn sounds when the lock button of keyless entry transmitter is pressed once. |
Lock/auto ON | During daytime, while the lighting switch is in the AUTO position, the horn sounds once when the lock is pressed once. |
W lock any time | The horn sounds when the lock button of keyless entry transmitter is pressed twice. (initial condition) |
Buzzer answer back | Adjusts the tone alarm answer back function. | Not sound buzzer | No function |
At keyless | Sounds when the keyless entry system is activated. |
At F.A.S.T.* | Sounds when KOS is activated (initial condition). |
At Both | Sounds when the keyless entry system or KOS is activated. |
Timer lock timer | Timer lock period adjustment | 30 sec | 30 seconds (initial condition) |
60 sec | 60 seconds |
120 sec | 120 seconds |
180 sec | 180 seconds |
Panic alarm switch | With/without panic alarm function | Disable | No function |
Enable | With function (initial condition) |
Duration of horn chirp | Horn sounding time during horn answer back | Short | 0.01 second (initial condition) |
Long | 0.02 second |
F.A.S.T.* key detect out from window | With/without KOS key exterior detection function | Enable | With function |
Disable | No function (initial condition) |
F.A.S.T.* feature | KOS function adjustment | Both enable | All KOS functions are enabled. (initial condition) |
Door Entry enable | Only door entry function is enabled. |
ENG start enable | Only engine starting function is enabled. |
Both disable | All KOS functions are disabled. |
F.A.S.T.* unlock disable time | Adjusts the door unlock inhibition period after door lock is activated. | 0 sec | 0 second |
3 sec | 3 seconds (Initial condition) |
5 sec | 5 seconds |
ACC power auto cut | Time to ACC power cut-off when the electric motor switch is in the ACC position | Disable | No function |
30 min | 30 minutes (initial condition) |
60 min | 60 minutes |
Comfort flasher switch time | Switch operation time to activate the comfort flasher function | Normal | 0.4 second (initial condition) |
Long | 0.8 second |
Intelligent washer | With/without intelligent washer function | Disable | No function (Initial condition) |
Enable | With function |
Coming home light | Disabling or enabling coming home light function | Disable | No function |
15 sec | The headlight illuminate for 15 seconds. |
30 sec | The headlight illuminate for 30 seconds. (initial condition) |
60 sec | The headlight illuminate for 60 seconds. |
180 sec | The headlight illuminate for 180 seconds. |
Welcome light | Disabling or enabling welcome light function | Disable | No function |
Small light | The taillight illuminate. (initial condition) |
Head light | The headlight illuminate. |
Rear wiper(linked reverse gear) | Adjustment of automatic rear window wiper operation with reverse gear engaged | Enable(R wip.ON) | Operates only when the rear wiper switch is ON. |
Enable(R/F wip.) | Operates only when the front or rear wiper switch is ON. (initial condition) |
Outer buzzer volume | KOS outer buzzer volume adjustment | Volume 1 | Quieter than the standard |
Volume 2 | Standard volume (Initial condition) |
Volume 3 | Louder than the standard |
A/C Recirculation Control | With/without inside/outside air automatic control function | Disable | No function |
Enable | With function (Initial condition) |
A/C Switch Control | With/without A/C automatic control function | Disable | No function |
Enable | With function (Initial condition) |
A/C Sensible temp. customize | Adjusting mean value for temperature setting | -2 | Decreases the control temperature two degrees than the temperature displayed on the LCD. |
-1 | Decreases the control temperature one degree than the temperature displayed on the LCD. |
0 | No change (Initial condition) |
1 | Increases the control temperature one degree than the temperature displayed on the LCD. |
2 | Increases the control temperature two degrees than the temperature displayed on the LCD. |
Eco Mode | Function to activate ECO mode air-conditioner | Eco | Activates the ECO mode. (initial condition) |
Comfort | Deactivates the ECO mode. |
FOOT / DEF Air outlet ratio | Changes air distribution rate for DEF/FOOT vents during manual operation. | Normal | D/F2 (Initial condition) |
FOOT > DEF | D/F1(more to FOOT vent): More air flows through FOOT vents. |
FOOT < DEF | D/F3(more to DEF vent): More air flows through DEF vents. |
FACE / FOOT Air outlet ratio | Changes air distribution rate for FACE/FOOT vents during manual operation. | Normal | B/L2 (Initial condition) |
FACE > FOOT | B/L1(more to FACE vent): More air flows through FACE vents. |
FACE < FOOT | B/L3(more to FOOT vent): More air flows through FOOT vents. |
Auto Rear Defogger(Engine Start) | Activates the rear window defogger when the ambient temperature is low.(The rear window defogger has never been activated since the electric motor switch was turned on last time) | Disable | No function (Initial condition) |
Enable | With function |
Charging Lid Light Timer | Adjustment of charging port courtesy light illumination time | Disable | Without function |
1min | 1min |
3min | 3min (initial condition) |
5min | 5min |
10min | 10min |
H/L(EV REMOTE Car finder) <Vehicles with MITSUBISHI remote control> | Time adjustment of the headlight by using the MITSUBISHI remote control | Disable | Without function |
15 sec | 15 sec. |
30 sec | 30 sec (initial condition) |
45 sec | 45 sec. |
Position(EV REMOTE Car finder) <Vehicles with MITSUBISHI remote control> | Time adjustment of the position light by using the MITSUBISHI remote control | Disable | Without function |
15 sec | 15 sec. |
30 sec | 30 sec (initial condition) |
45 sec | 45 sec. |
Gate auto open by Handle SW <Vehicles with power liftgate> | Opening operation by using the gate handle switch | Disable | No function |
Enable | With function (Initial condition) |