[Previous][Next]
INSPECTION
 
 
SWITCH RESISTANCE CHECK
 
 
 
SOS switch
Switch positionTerminal numberNormal condition
Press(-) 2 - (+) 11Continuity exists (2 ohms or less)
ReleaseNo continuity
 
Information switch
Switch positionTerminal numberNormal condition
Press(-) 2 - (+) 13Continuity exists (2 ohms or less)
ReleaseNo continuity
 
 
INDICATOR LIGHT CHECK
 
SOS switch
Indicator light colorApproximately 5 voltsTerminal numberNormal condition
RedNot applied(-) 2 - (+) 4Not illuminated
AppliedIlluminated
GreenNot applied(-) 2 - (+) 5Not illuminated
AppliedIlluminated
 
Information switch
Indicator light colorApproximately 5 voltsTerminal numberNormal condition
RedNot applied(-) 2 - (+) 15Not illuminated
AppliedIlluminated
GreenNot applied(-) 2 - (+) 16Not illuminated
AppliedIlluminated
 
 
ILLUMINATION CHECK
 
Battery positive voltageTerminal numberNormal condition
Not applied(-) 6 - (+) 9Not illuminated
AppliedIlluminated