![[Previous]](../../../buttons/fprev.png)
![[Next]](../../../buttons/fnext.png)
).Switch resistance check
| |||||||||||||||||||||
| Switch position | Terminal number | Normal condition | |
| OFF | 2 - 11 3 - 11 7 - 11 8 - 11 9 - 11 | No continuity | |
| ON | Combiner open/close switch | 1 - 2 | Continuity exists (2 Ω or less) |
| Angle adjustment switch (DOWN) | 7 - 11 | ||
| Angle adjustment switch (UP) | 2 - 11 | ||
| Brightness adjustment switch (-) | 9 - 11 | ||
| Brightness adjustment switch (+) | 3 - 11 | ||
Illumination check
|
| Battery voltage | Terminal number | Normal condition |
| Not applied | 1 (+) - 5 (-) | Not illuminated |
| Applied | Illuminated |