SOS switch
|
Switch position | Terminal number | Normal condition |
Press | (-) 2 - (+) 11 | Continuity exists (2 ohms or less) |
Release | No continuity |
Information switch
|
Switch position | Terminal number | Normal condition |
Press | (-) 2 - (+) 13 | Continuity exists (2 ohms or less) |
Release | No continuity |
SOS switch
|
Indicator light color | Approximately 5 volts | Terminal number | Normal condition |
Red | Not applied | (-) 2 - (+) 4 | Not illuminated |
Applied | Illuminated | ||
Green | Not applied | (-) 2 - (+) 5 | Not illuminated |
Applied | Illuminated |
Information switch
|
Indicator light color | Approximately 5 volts | Terminal number | Normal condition |
Red | Not applied | (-) 2 - (+) 15 | Not illuminated |
Applied | Illuminated | ||
Green | Not applied | (-) 2 - (+) 16 | Not illuminated |
Applied | Illuminated |
|
Battery positive voltage | Terminal number | Normal condition |
Not applied | (-) 6 - (+) 9 | Not illuminated |
Applied | Illuminated |