STEP 1. Using scan tool (M.U.T.-IIISE), read the ETACS-ECU DTC.
STEP 2. Using scan tool (M.U.T.-IIISE), check data list.
Check the input signal related to the operation of electric remote controlled mirror (folding/unfolding) function.(1) - Turn the ignition switch to ACC.
- Operate the electric remote controlled mirror switch (folding/unfolding switch): ON position.
| Item No. | Item name | Normal conditions | I91 | Mirror switch | ON | 111 | ACC switch | ON |
|
Item No. | Item name | Normal conditions |
I91 | Mirror switch | ON |
111 | ACC switch | ON |
OK: Normal condition is displayed.
Is the check result normal?
: Go to Step 3
. : GROUP 54A, ETACS - Inspection Procedure 13 "The remote controlled mirror switch (fold switch) signal is not received."
. : GROUP 54A, ETACS - Inspection Procedure 1 "The ignition switch (ACC) signal is not received"
.
STEP 3. Using scan tool (M.U.T.-IIISE), check data list.
Check the input signal related to the operation of electric remote controlled mirror (folding/unfolding) function.(1) - Turn the ignition switch to ACC.
- Turn on the folding/unfolding switch when the door mirrors are folded.
| Item No. | Item name | Normal conditions | 71 | Hold mirror open | ON | 72 | Hold mirror close | OFF |
|
Item No. | Item name | Normal conditions |
71 | Hold mirror open | ON |
72 | Hold mirror close | OFF |
OK: Normal condition is displayed.
(2) - Turn on the folding/unfolding switch when the door mirrors are unfolded.
| Item No. | Item name | Normal conditions | 71 | Hold mirror open | OFF | 72 | Hold mirror close | ON |
|
Item No. | Item name | Normal conditions |
71 | Hold mirror open | OFF |
72 | Hold mirror close | ON |
OK: Normal condition is displayed.
Is the check result normal?
Go to Step 5
.
Go to Step 4
.
STEP 4. Check of short to power supply, short to ground, and open circuit in +B2 line between fusible link and ETACS-ECU connector
STEP 5. Retest the system.