INITIALIZATION PROCEDURE
1. Move the selector lever to the P range and turn the ignition switch to the "LOCK" (OFF) position. Then, connect scan tool (M.U.T.-IIISE) to the data link connector.
2. Turn the ignition switch to the "ON" position, and then move the selector lever to the R range.
3. Depress the accelerator pedal while depressing the brake pedal. (Engine stops.) Use the scan tool (M.U.T.-IIISE) special function to execute "Reset (item No.1: Control learning value)" while holding them in applied position.
4. Set the selector lever to the P range.
5. Turn the ignition switch to the "LOCK" (OFF) position, and then wait for ten seconds.
6. Turn the ignition switch to the "ON" position. Execute the special function "CVT oil degradation level (item No.1: Clear CVT oil degradation level)" on the scan tool (M.U.T.-IIISE) to delete a transmission fluid deterioration level.